Datasheet

CD74AC151
8-LINE TO 1-LINE DATA SELECTOR/MULTIPLEXER
SCHS333 MARCH 2003
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range,
V
CC
= 1.5 V, C
L
= 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
55°C to
125°C
40°C to
85°C
UNIT
MIN MAX MIN MAX
t
PLH
169 152
ns
t
PHL
169 152
ns
t
PLH
186 169
ns
t
PHL
186 169
ns
t
PLH
228 207
ns
t
PHL
,
, or
228 207
ns
t
PLH
245 223
ns
t
PHL
,
, or
245 223
ns
t
PLH
153 139
ns
t
PHL
153 139
ns
t
PLH
169 153
ns
t
PHL
169 153
ns
switching characteristics over recommended operating free-air temperature range,
V
CC
= 3.3 V ± 0.3 V, C
L
= 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
55°C to
125°C
40°C to
85°C
UNIT
MIN MAX MIN MAX
t
PLH
4.7 18.9 4.9 17.1
ns
t
PHL
4.7 18.9 4.9 17.1
ns
t
PLH
5.2 20.9 5.4 19
ns
t
PHL
5.2 20.9 5.4 19
ns
t
PLH
6.4 25.5 6.6 23.2
ns
t
PHL
,
, or
6.4 25.5 6.6 23.2
ns
t
PLH
6.9 27.4 7.1 24.9
ns
t
PHL
,
, or
6.9 27.4 7.1 24.9
ns
t
PLH
4.3 17.1 4.4 15.5
ns
t
PHL
4.3 17.1 4.4 15.5
ns
t
PLH
4.7 18.9 4.9 17.2
ns
t
PHL
4.7 18.9 4.9 17.2
ns