Datasheet
CD54AC00, CD74AC00
QUADRUPLE 2-INPUT POSITIVE-NAND GATES
SCHS303C – JANUARY 2001 – REVISED JUNE 2002
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER TEST CONDITIONS V
CC
T
A
= 25°C
–40°C TO
85°C
–55°C TO
125°C
UNIT
CC
MIN MAX MIN MAX MIN MAX
1.5 V 1.4 1.4 1.4
I
OH
= –50 µA
3 V 2.9 2.9 2.9
4.5 V 4.4 4.4 4.4
V
OH
V
I
= V
IH
or V
IL
I
OH
= –4 mA 3 V 2.58 2.48 2.4
V
I
OH
= –24 mA 4.5 V 3.94 3.8 3.7
I
OH
= –50 mA
†
5.5 V 3.85
I
OH
= –75 mA
†
5.5 V 3.85
1.5 V 0.1 0.1 0.1
I
OL
= 50 µA
3 V 0.1 0.1 0.1
4.5 V 0.1 0.1 0.1
V
OL
V
I
= V
IH
or V
IL
I
OL
= 12 mA 3 V 0.36 0.44 0.5
V
I
OL
= 24 mA 4.5 V 0.36 0.44 0.5
I
OL
= 50 mA
†
5.5 V 1.65
I
OL
= 75 mA
†
5.5 V 1.65
I
I
V
I
= V
CC
or GND 5.5 V ±0.1 ±1 ±1 µA
I
CC
V
I
= V
CC
or GND, I
O
= 0 5.5 V 4 40 80 µA
C
i
10 10 10 pF
†
Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage to minimize
power dissipation. Test verifies a minimum 50-Ω transmission-line drive capability at 85°C and 75-Ω transmission-line drive capability at 125°C.
switching characteristics over recommended operating free-air temperature range,
V
CC
= 1.5 V, C
L
= 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
–40°C TO
85°C
–55°C TO
125°C
UNIT
(INPUT)
(OUTPUT)
MIN MAX MIN MAX
t
PLH
AorB
Y
83 91
ns
t
PHL
A
or
B
Y
83 91
ns
switching characteristics over recommended operating free-air temperature range,
V
CC
= 3.3 V ± 0.3 V, C
L
= 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
–40°C TO
85°C
–55°C TO
125°C
UNIT
(INPUT)
(OUTPUT)
MIN MAX MIN MAX
t
PLH
AorB
Y
2.7 9.3 2.6 10.2
ns
t
PHL
A
or
B
Y
2.7 9.3 2.6 10.2
ns