Datasheet
Figure 8 : Typical External Resistance vs. Pulse
Width at Various V
DD
and C
X.
Figure 9 : Typical External Capacitance vs.Pulse
Width at Various V
DD
and R
X.
Figure 10 : Typical Minimum Reset Pulse Width vs.
External Capacitance.
To calculate average power dissipation
(P) for less than 100% duty cycle :
P
100
= average power for 100% duty cycle
P=
τ
m
τ
T
P
100
where τ
m
= one-shot pulse width
τ
T
= trigger pulse period
=
e.g. : For tm … 600ms tT = 1000ms,
CX = 0.01µF,V
DD
=5V
P=
600
1000
103µW = 600µW
(see dotted line on graph)
Figure 11 : Average Power Dissipation for100% Duty Cycle vs. One-shot Pulse width.