In case, the cable assemblies for X102, X103, X104, X105, X107, X108 and/or X109 are
not installed on the product, each of the unused connector shall be closed with a sealing
cap, PROT-M12 MS-M1414148 manufactured by Phoenix. These sealing caps shall also to
be tightened with 0.6 Nm.
The product is powered by a 100V DC power supply either isolated or non-isolated. The
earthing system must be evaluated on system level for safe operation of the product.
2.1. General safety warnings
CAUTION!
During the UL evaluation, only Risk of Electrical Shock and Risk of Fire aspects
were investigated. Functional Safety aspects were not evaluated
CAUTION!
Suitable For Use On A Circuit Capable Of Delivering Not More Than 5000 rms
Symmetrical Amperes, 100 Volts DC Maximum
CAUTION!
Integral solid state short circuit protection does not provide branch circuit
protection. Branch circuit protection must be provided in accordance with the
Manufacturer Instructions, National Electrical Code and the Canadian
Electrical code, part I
CAUTION!
High temperature on electronics housing, Risk of burns
NOTICE:
Changes or modifications made to this equipment not expressly approved by
Prodrive Technologies B.V. may void the FCC authorization to operate this
equipment.
Table 2-1: Applicable safety norms
Norm
Description
Label
1
CSA-22.2 no. 274-17
Adjustable speed drives (Canada)
UL 61800-5-1
Power conversion equipment (US)
IEC-EN 61800-5-1
Adjustable Speed Electrical Power Drive
Systems - Safety Requirements -
Electrical, Thermal and Energy (Europe)
Note[1]: Depending on model, only applicable if logo is present on product label