User Manual
Table Of Contents
Confidential
Manual Carrier Controller 2020-07-30
SPD6752150121R21_EN.docx Page 5 of 25
1. Introduction
This manual is intended to cover basic installation and safety notes. During installation read and
follow these instructions carefully and completely. All required information is provided in this
manual.
This manual applies to the Carrier Controller, these can be identified by Prodrive Technologies PN:
Table 1-1: Carrier Controller PN
Item
Prodrive PN
Customer name
Customer PN
Carrier Controller Master (CE)
6752-1500-00xx
CCM
62802
Carrier Controller Master (CE) with DIO and ETH
6752-1500-01xx
CCM-IO-ETH
62803
Carrier Controller slave (CE)
6752-1500-02xx
CCS
62804
Carrier Controller slave (CE) with DIO
6752-1601-41xx
CCS-IO
62805
Carrier Controller Master (UL/CSA)
6752-1601-40xx
CCM, UL
64532
Carrier Controller Master (UL/CSA) with DIO and ETH
6752-1600-14xx
CCM-IO-ETH, UL
64533
Carrier Controller slave (UL/CSA)
6752-1600-15xx
CCS, UL
64534
Carrier Controller slave (UL/CSA) with DIO
6752-1601-42xx
CCS-IO, UL
64535
Note: xx = revision number
1.1. Product background
The product (Carrier controller) is primarily used as the motor drive in the field of distribution and
sortation. This sorter is able to receive packages (e.g. baggage or parcel) and transports this to the
correct end location where it exits the sorter. The sorter consists of a PLC controlling the whole
system, a rigid rail supplying infrastructures like power and communication and carriers each with
an individual carrier controller to drive the motors on the carrier.
2. Conditions of use
• Inspect the unit to ensure it was not damaged during shipment
• Product shall only be installed by adequately qualified personnel
• Product shall not be touched and/or installed and/or mounted with power enabled
• Product shall only be used in the environment specified in section 6
• Product shall be installed as specified in section 3 + 4
• Product is not compatible with RCD/RCM Type A or AC, where required a RCD/RCM type
B must be used
• Product maintenance shall only be performed by Prodrive Technologies
• Product repairs shall only be performed by Prodrive Technologies
• Product has a short circuit rating of 5kA
• The application shall protect X100 from external impact
• The PE conductor shall be connected at all times when power is supplied to the CC
• The motor shall be externally connected to PE
• Product does not incorporate motor overtemperature protection for the motor. Where
required, integral thermal protection shall be provided in or on the motor(s)
• This device does not incorporate internal motor overload protection for the motor and is
intended to be used with external or remote overload protection.
• Product is intended for industrial installations
o USA and Canada: For use only in industrial machinery NFPA 79 applications
• Do not put machine into operation before ensuring “(EMC) Directive 2014/30/EU” and
“Machinery Directive 2006/42/EC”
• Product has no protection for UV light
• The product shall be installed in an environment of pollution degree 3 or lower
• Product is not intended to be directly connected to the supply mains, but is intended to be
supplied by a transformer or similar means providing galvanic isolation. The product is
evaluated for use in Overvoltage category II only.
• The wiring assemblies for the connectors X102, X103, X104, X105, X107, X108 and X109
shall be tightened with a torque rating of 0.6 Nm.