User Manual

Confidential
Manual Carrier Controller 2020-07-30
SPD6752150121R21_EN.docx Page 19 of 25
Condition
Peak acceleration: 250m/s², Duration: 6ms, 1000 shocks in each
axis, Half-sine
Packed
Number of axes
3 (positive and negative for each)
Table 6-5: Random vibration test
Test procedure
IEC 60068-2-64:2008
Condition
Acc. to table A.6, Categories 2a, 2b, 2c, Unpacked
Number of axes
3
6.4. Ingres protection
Table 6-6: Ingress protection
Region
Description
Value
Unit
Remarks
EU
IP rating of carrier controller
IP54
[-]
Protection from dust and splashing water
based on NEN-EN-IEC60529
IP rating is only achieved with connector
cables and/or protection caps.
USA/CA
UL enclosure rating of carrier
controller
Type 5
[-]
Enclosure rating is achieved with connector
cables and/or protection caps. (Available from
Phoenix 1414148). See the corresponding
connector paragraph in chapter 3 for correct
cables and/or protection caps.
6.5. Disposal
This product should be treated as industrial waste when disposed. Dispose accordingly and comply
with all local regulations.