6. Environmental
6.1. Climatic Operating conditions
Table 6-1: Operating climatic conditions
Parameter
Description
Min
Typ
Max
Unit
Remarks
T
AMB
Operating ambient temperature
0
22
45
[°C]
RH
AMB
Operating humidity
0
95
[%]
Relative humidity (no condensation)
T
AMB/dT
Operating ambient temperature
change rate
-5
5
[°C/min]
H
ALT
Operating altitude AMSL
1000
[m]
AMSL (Above Mean Sea Level)
The product shall be installed in an environment of pollution degree 3 or lower.
The product does not have protection for UV-light.
6.2. Storage conditions
Table 6-2: Storage climatic conditions
Parameter
Description
Min
Typ
1
Max
Unit
Remarks
T
ST,AMB
Storage ambient temperature
-10
22
60
[°C]
RH
ST,AMB
Storage humidity
0
95
[%]
Relative humidity (no condensation)
T
ST,AMB/dT
Storage ambient temperature
change rate
-5
5
[°C/min]
H
ST,ALT
Storage altitude AMSL
1000
[m]
AMSL (Above Mean Sea Level)
t
SHELF
5
[yr]
Shelf life > 12 months requires
capacitor reforming, see Figure 6-1
Figure 6-1 Capacitor reforming
6.3. Shock and vibration
Table 6-3: Vibration test
Test procedure
IEC 60068-2-6
Condition
1Hz to 500 Hz; 20m/s² amplitude; 20 frequency cycles in each axis
Unpacked
Number of axes
3
Table 6-4: Shock test
Test procedure
IEC 60068-2-27