Datasheet

CC3100
www.ti.com
SWAS031D JUNE 2013REVISED FEBRUARY 2015
4.11.2.2 nRESET (External 32K)
Figure 4-7 shows the reset timing diagram for the external 32K first-time power-up and reset removal.
Figure 4-7. First-Time Power-Up and Reset Removal Timing Diagram (External 32K)
Table 4-3 describes the timing requirements for the external 32K first-time power-up and reset removal.
Table 4-3. First-Time Power-Up and Reset Removal Timing Requirements (External 32K)
Item Name Description Min Typ Max
Depends on
application board
T1 Supply settling time 3 ms
power supply, decap,
and so on
Hardware wakeup
T2 25 ms
time
Firmware initialization
T3 Initialization time time + radio 250 ms
calibration
Copyright © 2013–2015, Texas Instruments Incorporated Specifications 15
Submit Documentation Feedback
Product Folder Links: CC3100