Datasheet

CC3100
SWAS031D JUNE 2013REVISED FEBRUARY 2015
www.ti.com
Figure 4-6. First-Time Power-Up and Reset Removal Timing Diagram (32K XTAL)
Table 4-2 describes the timing requirements for the 32K XTAL first-time power-up and reset removal.
Table 4-2. First-Time Power-Up and Reset Removal Timing Requirements (32K XTAL)
Item Name Description Min Typ Max
Depends on
application board
T1 Supply settling time 3 ms
power supply, decap,
and so on
Hardware wakeup
T2 25 ms
time
32-kHz XTAL settling
+ firmware
T3 Initialization time 1.35 s
initialization time +
radio calibration
14 Specifications Copyright © 2013–2015, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: CC3100