User manual
www.ti.com
BATMON Registers
18.3.1.12 TEMP Register (Offset = 30h) [reset = X]
TEMP is shown in Figure 18-12 and described in Table 18-13.
Temperature Last Measured Temperature in Degrees Celsius This register may be read while
TEMPUPD.STAT = 1.
Figure 18-12. TEMP Register
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
RESERVED INT RESERVED
R-X R-X R-X
Table 18-13. TEMP Register Field Descriptions
Bit Field Type Reset Description
31-17 RESERVED R X
Software should not rely on the value of a reserved. Writing any
other value than the reset value may result in undefined behavior.
16-8 INT R X
Integer part (signed) of temperature value. Total value = INTEGER +
FRACTIONAL 2's complement encoding 0x100: Min value 0x1D8: -
40C 0x1FF: -1C 0x00: 0C 0x1B: 27C 0x55: 85C 0xFF: Max value
7-0 RESERVED R X
Software should not rely on the value of a reserved. Writing any
other value than the reset value may result in undefined behavior.
1325
SWCU117A–February 2015–Revised March 2015 Battery Monitor and Temperature Sensor
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated