Table 17-66. RECHARGECFG Register Field Descriptions (continued)
Bit Field Type Reset Description
2-0 PER_E R/W X
Number of 32 KHz clocks between activation of recharge controller
For recharge algorithm, PERIOD is the initial period when entering
powerdown mode. The adaptive recharge algorithm will not change
this register PERIOD will effectively be a 16 bit value coded in a 5 bit
mantissa and 3 bit exponent: This field sets the Exponent of the
Period. PERIOD=(PER_M*16+15)*2^PER_E
1268
AUX – Sensor Controller with Digital and Analog Peripherals SWCU117A–February 2015–Revised March 2015
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated