User manual
AUX – Sensor Controller Registers
www.ti.com
17.8.2.7 TRIGCNTLOAD Register (Offset = 18h) [reset = X]
TRIGCNTLOAD is shown in Figure 17-16 and described in Table 17-35.
Trigger Counter Load Stop counter control of TDC
Figure 17-16. TRIGCNTLOAD Register
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
RESERVED CNT
R-X R/W-X
Table 17-35. TRIGCNTLOAD Register Field Descriptions
Bit Field Type Reset Description
31-16 RESERVED R X
Software should not rely on the value of a reserved. Writing any
other value than the reset value may result in undefined behavior.
15-0 CNT R/W X
Selects the number of stop events that will be ignored by the TDC.
This can be used to measure multiple periods of a clock signal. The
value written to this field is loaded into the stop counter at the start of
each measurement. Note! Both values 0 and 1 will make the TDC
stop on the first event after the start event Note! Must not be
changed if STAT.STATE is not IDLE
1230
AUX – Sensor Controller with Digital and Analog Peripherals SWCU117A–February 2015–Revised March 2015
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated