User manual
www.ti.com
AUX – Sensor Controller Registers
17.8.2.6 TRIGCNT Register (Offset = 14h) [reset = X]
TRIGCNT is shown in Figure 17-15 and described in Table 17-34.
Trigger Counter Stop counter status/control of TDC
Figure 17-15. TRIGCNT Register
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
RESERVED CNT
R-X R/W-X
Table 17-34. TRIGCNT Register Field Descriptions
Bit Field Type Reset Description
31-16 RESERVED R X
Software should not rely on the value of a reserved. Writing any
other value than the reset value may result in undefined behavior.
15-0 CNT R/W X
Remaining number of stop events that will be ignored. Writing to this
register updates the value. The CNT will be loaded with the value of
TRIGCNTLOAD.CNT at the start of every measurement. When the
stop counter is enabled the first CNT-1 stop events is ignored after
which the TDC will stop measurement on event number CNT Note!
Must not be changed if STAT.STATE is not IDLE
1229
SWCU117A–February 2015–Revised March 2015 AUX – Sensor Controller with Digital and Analog Peripherals
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated