switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM TO LOAD
T
A
= 25°C
MIN
MAX
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
LOAD
CAPACITANCE
MIN TYP MAX
MIN MAX UNIT
t
PLH
A
Y
C 15 pF
3.8 5.5 8.5
ns
t
PHL
A Y C
L
= 15 pF
3.8 5.5 8.5
ns
t
PZH
OE
Y
C 15 pF
3.6 5.1 7.5
ns
t
PZL
OE
Y C
L
= 15 pF
3.6 5.1 7.5
ns
t
PHZ
OE
Y
C =15pF
4.8 6.8 10
ns
t
PLZ
OE
Y C
L
= 15 pF
4.8 6.8 10
ns
t
PLH
A
Y
C 50 pF
5.3 7.5 10.5
ns
t
PHL
A Y C
L
= 50 pF
5.3 7.5 10.5
ns
t
PZH
OE
Y
C 50 pF
5.1 7.1 9.5
ns
t
PZL
OE
Y C
L
= 50 pF
5.1 7.1 9.5
ns
t
PHZ
OE
Y
C =50pF
7 8.8 12
ns
t
PLZ
OE
Y C
L
= 50 pF
7 8.8 12
ns
operating characteristics, V
CC
= 5 V, T
A
= 25°C
PARAMETER TEST CONDITIONS TYP UNIT
C
pd