Datasheet

www.ti.com
BUF22821EVM-USB Software Overview
6.2.5 Reset Button
Pressing the Reset button in the BUF22821EVM-USB software performs two functions. First, a
General-Call Reset for the BUF22821 is performed. The status of the DAC registers after this General-Call
Reset default to 1000000000, or mid-supply. The second function performed after the Reset button is
pressed is that a Read DAC call is made to update the corresponding channel text boxes to the current
value for each channel.
6.2.6 Save to File Button
The register configurations of the BUF22821 DACs are displayed in both analog voltage and in
hexadecimal (refer to Figure 15). The DAC codes (that is, gamma voltages) can also be saved to a text
file (.txt) using the Save to File button.
Pressing the Save to File button opens a file-save dialog box similar to that shown in Figure 21. Pressing
the folder icon creates a new folder on your PC. It is a good idea to create a directory exclusively for
BUF22821 DAC code (gamma voltage) files. Enter a unique file name in the File name field to store your
BUF22821 register information. Press the OK button to save the file.
Figure 21. Save File Prompt
21
SBOU117September 2011 BUF22821EVM-USB Evaluation Board and Software Tutorial
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated