Figure 9. Volatile Control Registers Bit Legend
4.1.2 Factory-Programmed Register Values
The Control Registers are programmed at the factory to have a default value. Table 15 shows these
values.
Table 15. Default Register Values
Address Register Default Value
0x00 STATUS 0x01
0x01 CELL_CTL 0x10
0x02 BAL_CTL 0x00
0x03 CONFIG_1 0x00
0x04 CONFIG_2 0x81
0x05 PWR_CTL 0x00
4.1.3 Register Values When Polling
When the Polling button is pressed, the PWR_CTL register is forced to the value of 0x1F. This turns on all
measurement systems as well as the current comparator. This is shown in the Control Register Display.
Note that other bits are automatically updated (written) during polling but are not displayed (read). The
update rate of the bits during polling is in the 10s of milliseconds and does not make sense to display.
4.2 Control Registers Introduction
The Control Registers of the bq76925 are used to configure and control the device. A summary of the
read/write Control Registers follows. This user's guide, however, does not provide the necessary details
on the operation and settings of these registers that are given in the bq76925 data sheet . For those
details, see SLUSAM9.
Mousing over a bit in the Control Register section of the software displays a brief description of the bit.