Datasheet
bq34z100
SLUSAU1B –MAY 2012–REVISED DECEMBER 2012
www.ti.com
Table 20. Data Flash Summary (continued)
Subclass Default
Class Subclass Offset Name Data Type Min Value Max Value Units
ID Value
Gas Gauging 80 IT Cfg 25 Ra Filter U2 0 1000 500 —
Gas Gauging 80 IT Cfg 42 Fast Qmax Start U1 0 255 92 %
DOD %
Gas Gauging 80 IT Cfg 43 Fast Qmax End U1 0 255 96 %
DOD %
Gas Gauging 80 IT Cfg 44 Fast Qmax Start I2 0 4200 200 mV
Volt Delta
Gas Gauging 80 IT Cfg 67 Cell Termination I2 2500 3700 3000 mV
Voltage
Gas Gauging 80 IT Cfg 69 Cell Termination I2 0 4200 50 mV
Voltage Delta
Gas Gauging 80 IT Cfg 72 Simulation Res U2 0 65534 200 s
Relax Time
Gas Gauging 80 IT Cfg 76 User Rate-mA I2 –32767 32767 0 mA
Gas Gauging 80 IT Cfg 78 User Rate- I2 –32767 32767 0 mW/cW
mW/cW
Gas Gauging 80 IT Cfg 80 Reserve Cap- I2 0 9000 0 mAh
mAh
Gas Gauging 80 IT Cfg 82 Reserve Energy I2 0 14000 0 mWh/cWh
Gas Gauging 80 IT Cfg 86 Max Scale Back U1 0 15 4 —
Grid
Gas Gauging 80 IT Cfg 87 Cell Max Delta U2 0 65535 200 mV
V
Gas Gauging 80 IT Cfg 89 Cell Min Delta V U2 0 65535 0 mV
Gas Gauging 80 IT Cfg 91 Max Sim Rate U1 0 255 2 C/rate
Gas Gauging 80 IT Cfg 92 Min Sim Rate U1 0 255 20 C/rate
Gas Gauging 80 IT Cfg 93 Ra Max Delta U2 0 32767 44 mΩ
Gas Gauging 80 IT Cfg 95 Qmax Max U1 0 100 5 mAh
Delta %
Gas Gauging 80 IT Cfg 96 Cell DeltaV Max U2 0 65535 10 mV
Delta
Gas Gauging 80 IT Cfg 102 Fast Scale Start U1 0 100 10 %
SOC
Gas Gauging 80 IT Cfg 107 Charge Hys I2 0 2000 40 mV
Voltage Shift
Gas Gauging 81 Current 0 Dsg Current I2 0 2000 60 mA
Thresholds Threshold
Gas Gauging 81 Current 2 Chg Current I2 0 2000 75 mA
Thresholds Threshold
Gas Gauging 81 Current 4 Quit Current I2 0 1000 40 mA
Thresholds
Gas Gauging 81 Current 6 Dsg Relax Time U2 0 8191 60 s
Thresholds
Gas Gauging 81 Current 8 Chg Relax Time U1 0 255 60 s
Thresholds
Gas Gauging 81 Current 9 Quit Relax Time U1 0 63 1 s
Thresholds
Gas Gauging 81 Current 10 Max IR Correct U2 0 1000 400 mV
Thresholds
Gas Gauging 82 State 0 Qmax Cell 0 I2 0 32767 1000 mAh
Gas Gauging 82 State 2 Cycle Count U2 0 65535 0 —
Gas Gauging 82 State 4 Update Status H1 0x00 0x06 0x00 —
Gas Gauging 82 State 5 Cell V at Chg I2 0 5000 4200 mV