Datasheet
bq34z100
www.ti.com
SLUSAU1B –MAY 2012–REVISED DECEMBER 2012
Table 3. Control() Subcommands (continued)
CNTL FUNCTION CNTL DATA SEALED ACCESS DESCRIPTION
Returns the instantaneous current measured by the
CURRENT 0x0018 Yes
gauge
SEALED 0x0020 No Places the device in SEALED access mode
IT_ENABLE 0x0021 No Enables the Impedance Track algorithm
CAL_ENABLE 0x002D No Toggle calibration mode
RESET 0x0041 No Forces a full reset of the bq34z100
EXIT_CAL 0x0080 No Exit calibration mode
ENTER_CAL 0x0081 No Enter calibration mode
OFFSET_CAL 0x0082 No Reports internal CC offset in calibration mode
CONTROL_STATUS: 0x0000
Instructs the fuel gauge to return status information to Control addresses 0x00/0x01. The status word includes
the following information.
Table 4. CONTROL_STATUS Flags
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
High Byte — FAS SS CALMODE CCA BCA CSV —
Low Byte — — FULLSLEEP SLEEP LDMD RUP_DIS VOK QEN
FAS: Status bit that indicates the bq34z100 is in FULL ACCESS SEALED state. Active when set.
SS: Status bit that indicates the bq34z100 is in the SEALED State. Active when set.
CSV: Status bit that indicates a valid data flash checksum has been generated. Active when set.
CALMODE: Status bit that indicates the bq34z100 calibration function is active. True when set.
Default is 0.
CCA: Status bit that indicates the bq34z100 Coulomb Counter Calibration routine is active. Active
when set.
BCA: Status bit that indicates the bq34z100 Board Calibration routine is active. Active when set.
FULLSLEEP: Status bit that indicates the bq34z100 is in FULLSLEEP mode. True when set. The state
can only be detected by monitoring the power used by the bq34z100 because any
communication will automatically clear it.
SLEEP: Status bit that indicates the bq34z100 is in SLEEP mode. True when set.
LDMD: Status bit that indicates the bq34z100 Impedance Track algorithm using constant-power
mode. True when set. Default is 0 (constant-current mode).
RUP_DIS: Status bit that indicates the bq34z100 Ra table updates are disabled. True when set.
VOK: Status bit that indicates cell voltages are OK for Qmax updates. True when set.
QEN: Status bit that indicates the bq34z100 Qmax updates are enabled. True when set.
DEVICE TYPE: 0x0001
Instructs the fuel gauge to return the device type to addresses 0x00/0x01.
FW_VERSION: 0x0002
Instructs the fuel gauge to return the firmware version to addresses 0x00/0x01.
HW_VERSION: 0x0003
Instructs the fuel gauge to return the hardware version to addresses 0x00/0x01.
Copyright © 2012, Texas Instruments Incorporated Submit Documentation Feedback 11