Datasheet

bq3060
www.ti.com
SLUS928A MARCH 2009REVISED NOVEMBER 2009
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
MIN TYP MAX UNIT
PACK 25
Supply voltage V
BAT 3.8 V
VC2
+5
V
STARTUP
Start up voltage at PACK 5.2 5.5 V
V
shutdown
VPACK or VBAT, whichever is higher 3 3.2 3.3 V
VC1, BAT V
VC2
V
VC2
+5 V
VC2 V
VC3
V
VC3
+5
VC3 V
VC4
V
VC4
+5
V
IN
Input voltage range VC4 V
SRP
V
SRP
+5
VCn – VC(n+1), (n=1, 2, 3, 4 ) 0 5
PACK 25
SRP to SRN –0.3 1 V
C
REG27
External 2.7V REG capacitor 1 μF
T
OPR
Operating temperature –40 85 °C
Copyright © 2009, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Link(s): bq3060