This screen (Figure 10) shows the SBS data set along with additional ManufacturersAccess() command
information such as individual cell measurements. Additional Flag and Static data can be viewed by
selecting the appropriate tab at the bottom of the SBS screen.
Data such as SBS.ManufacturerName( ) is static and does not change. This data is viewed separately
using the Static Data tab available at the bottom of the screen.
Dragging the splitter bar (line that separates the Flags/Static data from SBS values) changes the height of
the Flags/Static Data display. Selecting | View |, then | Auto Arrange | returns the splitter bar to its original
location.
8.2 Setting Programmable bq3060 Options
The bq3060 data flash comes configured per the default settings detailed in the bq3060 data sheet.
Ensure that the settings are correctly changed to match the pack and application for the bq3060 solution
being evaluated.
IMPORTANT: The correct setting of these options is essential to get the best performance.
The settings can be configured using the Data Flash screen (Figure 11).
Figure 11. Data Flash Screen, 1st Level Safety Class
To read all the data from the bq3060 data flash, click on menu option | Data Flash | Read All |.
To write to a data flash location, click on the desired location, enter the data and press <Enter>, which
writes the entire tab of flash data, or select menu option | Data Flash | Write All |. The data flash must be
read before any writes are performed to avoid any incorrect data being written to the device.
The | File | Special Export | menu options allows the data flash to be exported, but it configures the
exported data flash to a learned state ready for mass production use.
12
bq3060EVM-001 SBS 1.1 Compliant Advanced Gas Gauge Battery SLUU342October 2009
Management Solution EVM
Submit Documentation Feedback