Figure 7. V
MM_DET_ON
and V
MM_DET_OFF
Threshold
BATTERY CONNECTION
Figure 8 shows the configuration for the 2-series cell battery connection.
Figure 8. 2-Series Cell Configuration
EXTERNAL CELL BALANCING
Higher cell balancing currents can be supported by means of a simple external network, as shown in Figure 9.
Figure 9. External Cell Balancing Configuration
R
CLAMP
ensures that both Q1 and Q2 remain off when balancing is disabled, and should be sized above 2 kΩ to
prevent excessive internal device current when the balancing network is activated. R
CB_EXT
determines the value
of the balancing current, and is dependent on the voltage of the balanced cell, as follows: