Datasheet

bq27541-G1
SLUSAL6C NOVEMBER 2011REVISED OCTOBER 2012
www.ti.com
Control( ): 0x00/0x01
Issuing a Control( ) command requires a subsequent 2-byte subcommand. These additional bytes specify the
particular control function desired. The Control( ) command allows the system to control specific features of the
bq27541-G1 during normal operation and additional features when the bq27541-G1 is in different access modes,
as described in Table 2.
Table 2. Control( ) Subcommands
SEALED
CNTL FUNCTION CNTL DATA DESCRIPTION
ACCESS
CONTROL_STATUS 0x0000 Yes Reports the status of DF Checksum, Hibernate, IT, etc.
DEVICE_TYPE 0x0001 Yes Reports the device type of 0x0541 (indicating bq27541-G1)
FW_VERSION 0x0002 Yes Reports the firmware version on the device type
HW_VERSION 0x0003 Yes Reports the hardware version of the device type
Reserved 0x0004 No Not to be used
RESET_DATA 0x0005 Yes Returns reset data
Reserved 0x0006 No Not to be used
PREV_MACWRITE 0x0007 Yes Returns previous Control() subcommand code
CHEM_ID 0x0008 Yes Reports the chemical identifier of the Impedance Track™ configuration
BOARD_OFFSET 0x0009 No Forces the device to measure and store the board offset
CC_OFFSET 0x000A No Forces the device to measure internal CC offset
CC_OFFSET_SAVE 0x000B No Forces the device to store the internal CC offset
DF_VERSION 0x000C Yes Reports the data flash version on the device
SET_FULLSLEEP 0x0010 Yes Set the [FullSleep] bit in Control Status register to 1
SET_HIBERNATE 0x0011 Yes Forces CONTROL_STATUS [HIBERNATE] to 1
CLEAR_HIBERNATE 0x0012 Yes Forces CONTROL_STATUS [HIBERNATE] to 0
SET_SHUTDOWN 0x0013 Yes Enables the SE pin to change state
CLEAR_SHUTDOWN 0x0014 Yes Disables the SE pin from changing state
SET_HDQINTEN 0x0015 Yes Forces CONTROL_STATUS [HDQIntEn] to 1
CLEAR_HDQINTEN 0x0016 Yes Forces CONTROL_STATUS [HDQIntEn] to 0
STATIC_CHEM_CHKSUM 0x0017 Yes Calculates chemistry checksum
SEALED 0x0020 No Places the bq27541-G1 in SEALED access mode
IT_ENABLE 0x0021 No Enables the Impedance Track™ algorithm
CAL_ENABLE 0x002d No Toggle bq27541-G1 calibration mode
RESET 0x0041 No Forces a full reset of the bq27541-G1
EXIT_CAL 0x0080 No Exit bq27541-G1 calibration mode
ENTER_CAL 0x0081 No Enter bq27541-G1 calibration mode
OFFSET_CAL 0x0082 No Reports internal CC offset in calibration mode
10 Submit Documentation Feedback Copyright © 2011–2012, Texas Instruments Incorporated