Datasheet

bq27530-G1
www.ti.com
SLUSAL5 DECEMBER 2012
Control( ): 0x00/0x01
Issuing a Control( ) command requires a subsequent 2-byte subcommand. These additional bytes specify the
particular control function desired. The Control( ) command allows the system to control specific features of the
bq27530-G1 during normal operation and additional features when the device is in different access modes, as
described in Table 3. Additional details are found in the bq27530-G1 Technical Reference Manual.
Table 3. Control( ) Subcommands
CNTL SEALED
CNTL FUNCTION DESCRIPTION
DATA ACCESS
CONTROL_STATUS 0x0000 Yes Reports the status of hibernate, IT, etc.
DEVICE_TYPE 0x0001 Yes Reports the device type (eg: bq27530)
FW_VERSION 0x0002 Yes Reports the firmware version on the device type
HW_VERSION 0x0003 Yes Reports the hardware version of the device type
PREV_MACWRITE 0x0007 Yes Returns previous MAC subcommand code
CHEM_ID 0x0008 Yes Reports the chemical identifier of the Impedance Track™ configuration
BOARD_OFFSET 0x0009 No Forces the device to measure and store the board offset
CC_OFFSET 0x000a No Forces the device to measure the internal CC offset
CC_OFFSET_SAVE 0x000b No Forces the device to store the internal CC offset
OCV_CMD 0x000c Yes Request the gauge to take a OCV measurement
BAT_INSERT 0x000d Yes Forces the BAT_DET bit set when the [BIE] bit is 0
BAT_REMOVE 0x000e Yes Forces the BAT_DET bit clear when the [BIE] bit is 0
SET_HIBERNATE 0x0011 Yes Forces CONTROL_STATUS [HIBERNATE] to 1
CLEAR_HIBERNATE 0x0012 Yes Forces CONTROL_STATUS [HIBERNATE] to 0
SET_SLEEP+ 0x0013 Yes Forces CONTROL_STATUS [SNOOZE] to 1
CLEAR_SLEEP+ 0x0014 Yes Forces CONTROL_STATUS [SNOOZE] to 0
Makes the programmed charge current to be half of what is calculated
DIV_CUR_ENABLE 0x0017 Yes
by the gauge charging algorithm.
Enable charger. Charge will continue as dictated by gauge charging
CHG_ENABLE 0x001A Yes
algorithm.
CHG_DISABLE 0x001B Yes Disable charger (Set CE bit of bq2416x)
Enables the gas gauge to control the charger while continuosly
GG_CHGRCTL_ENABLE 0x001C Yes
resetting the charger watchdog
GG_CHGRCTL_DISABLE 0x001D Yes The gas gauge stops resetting the charger watchdog
Makes the programmed charge current to be same as what is
DIV_CUR_DISABLE 0x001E Yes
calculated by the gauge charging algorithm.
DF_VERSION 0x001F Yes Returns the Data Flash Version
SEALED 0x0020 No Places device in SEALED access mode
IT_ENABLE 0x0021 No Enables the Impedance Track™ algorithm
RESET 0x0041 No Forces a full reset of the bq27530-G1
Copyright © 2012, Texas Instruments Incorporated Submit Documentation Feedback 11
Product Folder Links :bq27530-G1