Datasheet
ExitFromSLEEP
| AverageCurrent()|> SleepCurrent
| AverageCurrent()| ≤ SleepCurrent
OR
CurrentisDetectedaboveI
WAKE
ExitFrom SLEEP
(Hosthasset ControlStatus
[HIBERNATE]=1
OR
V
CELL
< HibernateVoltage
Fuel gauginganddata
updatedevery 1s
NORMAL
Fuel gauginganddata
updated every 20 seconds
SLEEP
Disableallbq27500/1
subcircuitsexceptGPIO
.
Negate BAT_GD
HIBERNATE
EntrytoSLEEP
OperationConfiguration [SLEEP]=1
AND
Wakeup From HIBERNATE
Communication Activity
AND
CommaddressisNOT for
bq27500/1
ExitFrom HIBERNATE
BatteryRemoved
POR
Checkforbatteryinsertion
fromHALT state.
Nogauging
BAT INSERT CHECK
EntrytoNORMAL
Flags [BAT_DET]=1
ExitFrom NORMAL
Flags [BAT_DET]=0
ExitFrom SLEEP
Flags [BAT_DET]=0
Flags [BAT_DET]=0
WAIT_HIBERNATE
Fuel gauginganddata
updatedevery 20 seconds
BAT_GD unchanged
ExitFromWAIT_HIBERNATE
Cellrelaxed
AND
| AverageCurrent()|<Hibernate
OR
Cellrelaxed
AND
V
CELL
< HibernateVoltage
SystemShutdown
ExitFrom WAIT_HIBERNATE
HostmustsetControlStatus
[HIBERNATE]=0
AND
V
CELL
> HibernateVoltage
ExitFrom HIBERNATE
Communication Activity
ANDCommaddressisfor
bq27500/1
bq27500 /1 clearsControlStatus
[HIBERNATE] =0
RecommendHostalsoset Control
Status [HIBERNATE] =0
5.7.4 HIBERNATE MODE
bq27500
bq27501
System-Side Impedance Track™ Fuel Gauge
SLUS785D – SEPTEMBER 2007 – REVISED APRIL 2008
www.ti.com
Figure 5-2. Power Mode Diagram
HIBERNATE mode should be used when the system equipment needs to enter a low-power state, and
minimal gauge power consumption is required. This mode is ideal when a system equipment is set to its
own HIBERNATE, SHUTDOWN, or OFF modes.
Before the fuel gauge can enter the HIBERNATE mode, the system must set the [HIBERNATE] bit of the
CONTROL_STATUS register. The gauge waits to enter HIBERNATE mode until it has taken a valid OCV
measurement and the magnitude of the average cell current has fallen below Hibernate Current. The
gauge can also enter HIBERNATE mode if the cell voltage falls below Hibernate Voltage, and a valid
OCV measurement has been taken. The gauge remains in HIBERNATE mode until the system issues a
direct I
2
C command to the gauge or a POR occurs. I
2
C communication that is not directed to the gauge
does not wake the gauge.
FUNCTIONAL DESCRIPTION28 Submit Documentation Feedback