Datasheet
www.ti.com
G003
Power
Supply#1
bqHYBRID
EVM
BAT+
(J4)
BAT–
R
36
0.25W
L
W
SYS
(J3)
AC
(J1)
EN
500
0.25W
W
B0235-05
PROCEDURE
Figure 2-7. BAT+ Waveform at No Load
13. No Battery; Charger Connected to System Directly. Connect the 500- Ω , 0.25-W resistor across J4
(BAT+ and BAT–). Make sure the test setup has been changed to setup E, as shown in Fig. 8. Verify
the red LED (D3) and green LED (D4) are on and the green LED (D2) is off. Verify the voltage across
BAT+ and BAT– is regulated between 4.160 V and 4.240 V.
Figure 2-8. Test Setup E
SLUU214A – December 2004 – Revised June 2007 Basic Functions Evaluation 11
Submit Documentation Feedback