Datasheet

www.ti.com
Printed-Circuit-Board Layout Guideline
6. The output capacitor ground connections need to be tied to the same copper that connects to the
input capacitor ground before connecting to the system ground.
7. Use single ground connection to tie the charger power ground to the charger analog ground. Just
beneath the IC, use analog ground copper pour, but avoid the power pins in order to reduce inductive
and capacitive noise coupling.
8. Route the analog ground separately from the power ground. Connect the analog ground, and then
connect the power ground separately. Connect analog ground and power ground together using power
pad as the single ground connection point. Or use a 0-Ω resistor to tie analog ground to the power
ground. (The power pad must tie to the analog ground in this case, if possible).
9. Place the decoupling capacitors next to the IC pins, and make the trace connection as short as
possible.
10. It is critical that the exposed power pad on the backside of the IC package be soldered to the PCB
ground. Ensure that sufficient thermal vias are located directly under the IC, connecting to the ground
plane on the other layers.
9
SLUU507AJune 2011Revised September 2011 bq24735/725A Battery Charger Evaluation Module
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated