The power path management feature allows the bq24272 to power the system from a high efficiency DC to DC
converter while simultaneously and independently charging the battery. The charger monitors the battery current
at all times and reduces the charge current when the system load requires current above the input current limit.
This allows for proper charge termination and timer operation. The system voltage is regulated to the battery
voltage but will not drop below 3.5V. This minimum system voltage support enables the system to run with a
defective or absent battery pack and enables instant system turn-on even with a totally discharged battery or no
battery. The power-path management architecture also permits the battery to supplement the system current
requirements when the adapter cannot deliver the peak system currents. This enables the use of a smaller
adapter.
The battery is charged in three phases: conditioning, constant current and constant voltage. In all charge phases,
an internal control loop monitors the IC junction temperature and reduces the charge current if the internal
temperature threshold is exceeded. Additionally, the bq24272 offers a voltage-based battery pack thermistor
monitoring input (TS) that monitors battery temperature for safe charging.
2 Submit Documentation Feedback Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s) :bq24272