Datasheet
bq24272
www.ti.com
SLUSB09 –JUNE 2012
Once the battery is charged enough to where the system voltage begins to rise above V
SYS(REG)
(approximately
3.5V), the battery FET is turned on fully and the battery is charged with the full programmed charge current set
by the I
2
C interface, I
CHARGE
. The slew rate for fast charge current is controlled to minimize the current and
voltage over-shoot during transient. The charge current is regulated to I
CHARGE
until the battery is charged to the
regulation voltage. Once the battery voltage is close to the regulation voltage, V
BATREG
, the charge current is
tapered down as shown in Figure 1 while the SYS output remains connected to the battery. The voltage
regulation feedback occurs by monitoring the battery-pack voltage between the BAT and PGND pins. The
V
BATREG
is targeted for single-cell voltage batteries and has an adjustable regulation voltage (3.5V to 4.44V)
programmed using the I
2
C interface.
The bq24272 monitors the charging current during the voltage regulation phase. Once the termination threshold,
I
TERM
, is detected and the battery voltage is above the recharge threshold, the bq24272 terminates charge and
turns off the battery charging FET and enters battery detection. If a battery is detected (See Battery Detection
section), the bq24272 enters charge done. The system output is regulated to the V
SYS(REG)
and supports the full
current available from the input and the battery supplement mode is available (see the “Dynamic Power Path
Management” section for more details). The termination current level is programmable. To disable the charge
current termination, the host sets the charge termination bit (TE) of charge control register to 0, refer to I
2
C
section for details.
A new charge cycle is initiated when one of the following conditions is detected:
1. The battery voltage falls below the V
BATREG
-V
RCH
threshold.
2. V
IN
toggle
3. CE bit toggle or RESET bit is set
4. HI-Z bit toggle
Battery Detection
When termination conditions are met, a battery detection cycle is started. During battery detection, I
DETECT
is
pulled from V
BAT
for t
DETECT
to verify there is a battery. If the battery voltage remains above V
DETECT
for the full
duration of t
DETECT
, a battery is determined to present and the IC enters “Charge Done”. If V
BAT
falls below
V
DETECT
, a “Battery Not Present” fault is signaled and battery detection continues. The next cycle of battery
detection, the bq24272 turns on I
BATSHORT
for t
DETECT
. If V
BAT
rises to V
DETECT
, the current source is turned off and
after t
DETECT
, the battery detection continues through another current sink cycle. Battery detection continues until
charge is disabled or a battery is detected. Once a battery is detected, the fault status clears and a new charge
cycle begins. Battery detection is not run when termination is disabled.
Dynamic Power Path Management (DPPM)
The bq24272 features a SYS output that powers the external system load connected to the battery. This output
is active whenever a source is connected to IN or BAT. The following sections discuss the behavior of SYS with
a source connected to the supply or a battery source only.
Input Source Connected
When a valid input source is connected, the buck converter turns on to power the load on SYS. The STAT/INT
show an interrupt with 128µs pulse to tell the host that something has changed. The FAULT bits read normal,
and the Supply Status register shows that a new supply is connected. The CE bit (bit 1) in the control register
(0x02) determines whether a charge cycle is initiated. By default, the bq24272 (/CE=0) enables a charge cycle
when a valid input source is connected. When the CE bit is 1 and a valid input source is connected, the battery
FET is turned off and the SYS output is regulated to the V
SYS(REG)
programmed by the V
BATREG
threshold in the
I
2
C register. A charge cycle is initiated when the CE bit is written to a 0.
When the CE bit is a 0 and a valid source is connected to IN, the buck converter starts up and a charge cycle is
initiated. When V
BAT
is high enough that V
SYS
is > V
SYS(REG)
, the battery FET is turned on and the SYS output is
connected to BAT. If the SYS voltage falls to V
SYS(REG)
, it is regulated to that point to maintain the system output
even with a deeply discharged or absent battery. In this mode, the SYS output voltage is regulated by the buck
converter and the battery FET linearly regulates the charge current into the battery. The current from the supply
is shared between charging the battery and powering the system load at SYS. The dynamic power path
Copyright © 2012, Texas Instruments Incorporated Submit Documentation Feedback 11
Product Folder Link(s) :bq24272