Datasheet

bq24090, bq24091
bq24092, bq24093
SLUS968A JANUARY 2010REVISED FEBRUARY 2010
www.ti.com
ELECTRICAL CHARACTERISTICS (continued)
Over junction temperature range 0°C T
J
125°C and recommended supply voltage (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
QUIESCENT CURRENT
I
OUT(PDWN)
Battery current into OUT pin V
IN
= 0V 1
mA
I
OUT(DONE)
OUT pin current, charging terminated V
IN
= 6V, V
OUT
> V
OUT(REG)
6
I
IN(STDBY)
Standby current into IN pin TS = LO, V
IN
6V 125 mA
TS = open, V
IN
= 6V, TTDM – no load on OUT pin,
I
CC
Active supply current, IN pin 0.8 1.0 mA
V
OUT
> V
OUT(REG)
, IC enabled
BATTERY CHARGER FAST-CHARGE
V
OUT(REG)
Battery regulation voltage V
IN
= 5.5V, I
OUT
= 25mA, (V
TS-45°C
V
TS
V
TS-0°C
) 4.16 4.2 4.23 V
Battery hot regulation Voltage,
V
O_HT(REG)
V
IN
= 5.5V, I
OUT
= 25mA, V
TS-60°C
V
TS
V
TS-45°C
4.02 4.06 4.1 V
bq24092/3
V
OUT(REG)
> V
OUT
> V
LOWV
; V
IN
= 5V, ISET2=Lo,
Programmed Output “fast charge”
I
OUT(RANGE)
10 1000 mA
current range
R
ISET
= 675 to 10.8k
Adjust VIN down until I
OUT
= 0.5A, V
OUT
= 4.15V,
V
DO(IN-OUT)
Drop-Out, VIN – VOUT 325 520 mV
R
ISET
= 675 , ISET2=Lo (adaptor mode); Tj 100°C
I
OUT
Output “fast charge” formula V
OUT(REG)
> V
OUT
> V
LOWV
; V
IN
= 5V, ISET2 = Lo K
ISET
/R
ISET
A
R
ISET
= K
ISET
/I
OUT
; 50 < IOUT < 800 mA 510 540 565
K
ISET
Fast charge current factor R
ISET
= K
ISET
/I
OUT
; 25 < IOUT < 50 mA 480 527 580 A
R
ISET
= K
ISET
/I
OUT
; 10 < IOUT < 25 mA 350 520 680
PRECHARGE – SET BY PRETERM PIN
Pre-charge to fast-charge transition
V
LOWV
2.4 2.5 2.6 V
threshold
Deglitch time on pre-charge to
t
DGL1(LOWV)
70 ms
fast-charge transition
Deglitch time on fast-charge to
t
DGL2(LOWV)
32 ms
pre-charge transition
I
PRE-TERM
Refer to the Termination Section
V
OUT
< V
LOWV
; R
ISET
= 1080; %I
OUT-
Pre-charge current, default setting 18 20 22
R
PRE-TERM
= High Z
CC
%
PRECHG
Pre-charge current formula R
PRE-TERM
= K
PRE-CHG
(/%) × %
PRE-CHG
(%) R
PRE-TERM
/K
PRE-CHG%
V
OUT
< V
LOWV
, V
IN
= 5V, R
PRE-TERM
= 2k to 10k;
R
ISET
= 1080 , R
PRE-TERM
= K
PRE-CHG
× %I
FAST-CHG
, 90 100 110 /%
where %I
FAST-CHG
is 20 to 100%
K
PRE-CHG
% Pre-charge Factor
V
OUT
< V
LOWV
, V
IN
= 5V, R
PRE-TERM
= 1k to 2k;
R
ISET
= 1080, R
PRE-TERM
= K
PRE-CHG
× %I
FAST-CHG
, 84 100 117 /%
where %I
FAST-CHG
is 10% to 20%
TERMINATION – SET BY PRE-TERM PIN
Termination Threshold Current, default V
OUT
> V
RCH
; R
ISET
= 1k; %I
OUT-
9 10 11
setting R
PRE-TERM
= High Z
CC
%
TERM
Termination Current Threshold
R
PRE-TERM
= K
TERM
(/%) × %TERM (%) R
PRE-TERM
/ K
TERM
Formula
V
OUT
> V
RCH
, V
IN
= 5V, R
PRE-TERM
= 2k to 10k ;
R
ISET
= 750 K
TERM
× %I
FAST-CHG
, where %I
FAST-CHG
182 200 216
is 10 to 50%
K
TERM
% Term Factor /%
V
OUT
> V
RCH
, V
IN
= 5V, R
PRE-TERM
= 1k to 2k ; R
ISET
174 199 224
= 750 K
TERM
× %Iset, where %Iset is 5 to 10%
Current for programming the term. and
I
PRE-TERM
pre-chg with resistor. I
Term-Start
is the R
PRE-TERM
= 2k, V
OUT
= 4.15V 71 75 81 mA
initial PRE-TERM current.
%TERM Termination current formula R
TERM
/ K
TERM
%
t
DGL(TERM)
Deglitch time, termination detected 29 ms
Elevated PRE-TERM current for,
I
Term-Start
t
Term-Start
, during start of charge to 80 85 92 mA
prevent recharge of full battery,
Elevated termination threshold initially
t
Term-Start
1.25 min
active for t
Term-Start
4 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated
Product Folder Link(s): bq24090 bq24091