Datasheet
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
0.6
1.8
V -Voltage-V
TS
NormalizedOUTCurrentandV -V
REG
60 Cto45 C
HOT TEMP
4.06V
Regulation
o o
I
OUT
V
OUT
0
0.2
0.4
0.8
1
1.2
1.4
1.6
For<45 C,4.2VRegulation
o
} HotFault
NoOperation
DuringCold
Fault
Cold
Fault
ICDisable}
0 C
o
< 48 C
o
60 C
o
10 C
o
100%ofProgrammed
Current
50%
Termination
Disable
bq24090, bq24091
bq24092, bq24093
www.ti.com
SLUS968A –JANUARY 2010–REVISED FEBRUARY 2010
ISET
An external resistor is used to Program the Output Current (50 to 800mA) and can be used as a current monitor.
R
ISET
= K
ISET
÷ I
OUT
(1) (1)
Where:
I
OUT
is the desired fast charge current;
K
ISET
is a gain factor found in the electrical specification
For greater accuracy at lower currents, part of the sense FET is disabled to give better resolution. Figure 15
shows the transition from low current to higher current. Going from higher currents to low currents, there is
hysteresis and the transition occurs around 0.15A.
The ISET resistor is short protected and will detect a resistance lower than Ⅹ340Ω. The detection requires at
least 80mA of output current. If a “short” is detected, then the IC will latch off and can only be reset by cycling the
power. The OUT current is internally clamped to a maximum current between 1.1A and 1.35A and is independent
of the ISET short detection circuitry, as shown in Figure 23. Also, see Figure 9 and Figure 10.
Figure 22. Operation Over TS Bias Voltage
Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 19
Product Folder Link(s): bq24090 bq24091