Datasheet
Boost Mode: Vbat = 3.7 V
Vsw
Vprnid_AC coupled
C2
C1
www.ti.com
Test Summary
2.3.2.6 Switch to Boost Mode
1. Turn off and disconnect PS#1
2. If the constant voltage load connected from BAT+ to GND is not a four-quadrant supply (sources
current) remove the load and use the power source disconnected in step one, set to 3.7 V and 2 A
current limit and connect between BAT+ and GND
3. Apply 10 Ω (5 W or greater) across J5 (PMID(+) to GND(–)
4. Uncheck the OTG Low box in the GUI
5. Select OTG in the Configuration drop-down window
6. Verify V
PMID
to GND on J5 is between 4.9 V and 5.3 V
7. Verify scope measurement (See Figure 6)
C1 (AC coupled 20 mV/div): Vac_PMID (TP20 to GND) – Ripple excluding high frequency spikes
C2 (5 V/div): Vdc_SW (TP2) - Frequency between 1.2 MHz and 1.7 MHz, Duty cycle between 67%
and 74%
Figure 5. Boost Mode Ripple and Duty Cycle; V
BAT
= 3.7 V
2.3.2.7 Verify Device ID JEITA shown in software matches Table 5
Table 5. Device ID JEITA Settings
Assembly Number EVM Part Number Device ID JEITA
PWR021-001 bq24190EVM-021 100 Disabled
PWR021-003 bq24192EVM-021 101 Disabled
PWR021-004 bq24192iEVM-021 011 Disabled
PWR021-005 bq24193EVM-021 101 Enabled
PWR021-006 bq24196EVM-021 101 Disabled
PWR021-007 bq24292iEVM-021 011 Disabled
9
SLUUA14C–October 2012–Revised August 2013 bq24190/2/2i/3/6 and bq24292i EVM (PWR021) User's Guide