2.3.2 Charge Voltage and Current Regulation of V
IN
and Device ID Verification
Follow the steps and verify the outputs and IC for the EVM.
2.3.2.1 Software setup (all of Section 2.3.2.1 is done in the GUI):
1. Device address: bq24190/192/192i/193/196 (6B) and bq24292i
2. Click the Read button
3. Select Disabled for I
2
C Watchdog Timer Limit
4. Set Input Voltage Limit to 4.2 V
5. Set Input Current Limit to 500 mA
6. Set Charge Voltage Limit to 4.208 V
7. Set Fast Charge Current, ICHG to 512 mA
8. Set Pre-Charge Current to 256 mA
9. Deselect Enable Termination (see the following image)
10. Click the Read button twice
Observe Everything normal at FAULT box
Observe D1 (STAT) is on, except the bq24192i/292iEVM
Observe D2 (/PG) is on for bq24190/192/192i/193/196/292iEVM
2.3.2.2 Enable Load#1 from Section 2.2 step 4. Measure the voltage across J2 at two different points:
Measure V(J2(SYS), J2(GND)) = 3.65 V ±300 mV
Measure V(J2(BAT), J2(GND)) = 2.5V ±200 mV
7
SLUUA14COctober 2012Revised August 2013 bq24190/2/2i/3/6 and bq24292i EVM (PWR021) User's Guide