Datasheet

bq24160, bq24160A
bq24161, bq24161B
bq24163, bq24168
www.ti.com
SLUSAO0E NOVEMBER 2011REVISED NOVEMBER 2013
1. No input supply connected.
2. HZ_MODE = 1
3. CD pin connected high
DEFAULT Mode
DEFAULT mode is used when I
2
C communication is not available. DEFAULT mode is entered in the following
situations:
1. When the charger is enabled and V
BAT
< V
BATGD
before I
2
C communication is established
2. When the watchdog timer expires without a reset from the I
2
C interface and the safety timer has not expired.
3. When the device comes out of any fault condition (sleep mode, OVP, faulty adapter mode, etc.) before I
2
C
communication is established
In DEFAULT mode, the I
2
C registers are reset to the default values. The 27-minute safety timer (no timer for
bq24168) is reset and starts when DEFAULT mode is entered. The default value for VBATREG is 3.6V, and the
default value for I
CHARGE
is 1A. The input current limit for the IN input is set to 1.5A. The input current limit for the
USB input is determined by the D+/D– detection (bq24160/3) or PSEL (bq24161/1B/8). PSEL and D+/D–
detection have no effect on the IN input. Default mode is exited by programming the I
2
C interface. Once I
2
C
communication is established, PSEL has no effect on the USB input. Note that if termination is enabled and
charging has terminated, a new charge cycle is NOT initiated when entering DEFAULT mode.
Copyright © 2011–2013, Texas Instruments Incorporated Submit Documentation Feedback 19
Product Folder Links: bq24160 bq24160A bq24161 bq24161B bq24163 bq24168