Datasheet
To
Computer
USB port
USB Interface
Adapter
I/O
USB
TexasInstruments
©2006
10-pin
Ribbon
Cable
To EVM
Test Summary
www.ti.com
2.2.4 Meters
Two equivalent voltage meters and two equivalent current meters. The current meters must be able to
measure 2-A current.
2.2.5 Computer
A computer with at least one USB port and a USB cable. The bq24153_6_8 evaluation software must be
properly installed.
2.2.6 HPA172 Communication Kit (USB TO GPIO)
A HPA172 USB to I2C communication kit.
2.2.7 Software
Download BQ24153_6_8Setup.zip from the charger's product folder, unzip the file and double-click on the
“SETUP.EXE” file. Follow the installation steps.
2.3 Recommended Test Equipment Setup
1. Set Power Supply #1 for 5 V ± 100 mVdc, 2-A. ±0.1-A current limit, and then turn off supply.
2. Connect the output of Power Supply #1 in series with a current meter (multimeter) to J1 (DC+, DC–).
3. Connect a voltage meter across J1 (DC+, DC–).
4. Connect the Load #2 in series with a current meter (multimeter) to J2 (BAT+, BAT–). Ensure that a
voltage meter is connected across J2 (BAT+, BAT–). Turn on the Load #2. Use the constant voltage
mode. Set the output voltage to 2.5 V.
5. Turn off Load #2.
6. Connect J5 to HPA172 kit by the 10-pin ribbon cable. Connect the USB port of the HPA172 kit to the
USB port of the computer. The connections are shown in Figure 1.
Figure 1. Connections of HPA172 Kit
7. Install jumpers per Table 1
Table 1. Factory Jumper Settings
Spin JMP1 JMP2 JMP3 JMP4 JMP5
HPA256-001 (-LED-) ON (-LO-) ON OFF (-LO-) ON ON
(bq24153A)
HPA256-002 (-LED-) ON (-HI-) ON OFF (-LO-) ON ON
(bq24156A)
4
bq24153A/56A/57/58/59 Fully Integrated, Switch-Mode, One-Cell, Li-Ion ChargerSLUU453B–November 2010–Revised September 2012
With Full USB Compliance and USB-OTG Support EVM