Datasheet
To
Computer
USB port
USB Interface
Adapter
I/O
USB
TexasInstruments
©2006
10-pin
Ribbon
Cable
To EVM
www.ti.com
Test Summary
2.2.6 HPA172 Communication Kit (USB TO GPIO)
A HPA172 USB-to-I
2
C communication kit.
2.2.7 Software
Download BQ2414xSW.zip from the charger's product folder, unzip the file, and double-click on the
SETUP.EXE file. Follow the installation steps.
2.3 Recommended Test Equipment Setup
1. Set Power Supply #1 for 5 V ± 100 mVdc, 2-A ± 0.1-A current limit, and then turn off supply.
2. Connect the output of Power Supply #1 in series with a current meter (multimeter) to J1 (VIN, GND).
3. Connect a voltage meter across J4 and J5 (VIN, GND).
4. Connect the Load #2 in series with a current meter (multimeter) to J7 (BAT, GND). Ensure that a
voltage meter is connected across J10 or TP10 and J11 or TP11 (BAT, GND).
5. Turn on the Load #2. Use the constant voltage mode. Set the output voltage to 2.5 V.
6. Turn off Load #2.
7. Connect the HPA172 USB-TO-GPIO to J2 using the 10-pin ribbon cable. Connect the USB port of the
HPA172 kit to the USB port of the computer. The connections are shown in Figure 1.
Figure 1. Connections of HPA172 Kit
8. Install jumpers per Section 1.5
9. After the preceding steps have been performed, the test setup for charging from VIN is shown in
Figure 2
5
SLUU495A–October 2011–Revised September 2012 bq24140, Fully Integrated, Dual-Input, Switch-Mode, One-Cell, Li-Ion Charger
With Full USB Compliance and USB-OTG Support EVM
Submit Documentation Feedback