Datasheet
Test Summary
www.ti.com
Observe → D1 (STAT) ON
Open JP4 (set fast charge)
Measure → I(J2(VBAT)) = 2A ± 200mA
Observe → D1 (STAT) ON
Open 2-3 of JP1 (external TS)
Measure → I(J2(VBAT)) = 0A ± 100mA
Observe → D1 (STAT) BLINK
Connect 2-3 of JP1 (Internal TS)
Measure → I(J2(VBAT)) = 2A ± 200mA
Observe → D1 (STAT) ON
5. Charge Voltage Regulation
Observe → I(J2(VBAT)) decreases from 2A while V(J2(VBAT)) becomes constant.
6. Test Complete
Turn off the power supply and remove all connections from the unit under test (UUT).
6
600-kHz Synchronous Switch-Mode Li-Ion and Li-Polymer Host-Controlled SLVU495B–July 2011–Revised January 2012
Battery Charger With Integrated MOSFETs
Submit Documentation Feedback