Test Summary
www.ti.com
Observe D1 (STAT) ON
Open JP4 (set fast charge)
Measure I(J2(VBAT)) = 2A ± 200mA
Observe D1 (STAT) ON
Open 2-3 of JP1 (external TS)
Measure I(J2(VBAT)) = 0A ± 100mA
Observe D1 (STAT) BLINK
Connect 2-3 of JP1 (Internal TS)
Measure I(J2(VBAT)) = 2A ± 200mA
Observe D1 (STAT) ON
5. Charge Voltage Regulation
Observe I(J2(VBAT)) decreases from 2A while V(J2(VBAT)) becomes constant.
6. Test Complete
Turn off the power supply and remove all connections from the unit under test (UUT).
6
600-kHz Synchronous Switch-Mode Li-Ion and Li-Polymer Host-Controlled SLVU495BJuly 2011Revised January 2012
Battery Charger With Integrated MOSFETs
Submit Documentation Feedback