Datasheet
Test Summary
www.ti.com
2 Test Summary
2.1 Definitions
This procedure details how to configure the HPA624 evaluation board. On the test procedure the following
naming conventions are followed.
VXX: External voltage supply name (VIN, VBAT, VTS)
LOADW; External load name (LOADR, LOADI)
V(TPyYy): Voltage at internal test point TPyyy. For example, V(TP1) means the voltage at
TP1.
V(Jxx): Voltage at jack terminal Jxx.
V(TP(XXX)): Voltage at test point “XXX”. For example, V(REGN) means the voltage at the test
point which is marked as “REGN”.
V(XXX, YYY): Voltage across point XXX and YYY.
I(JXX(YYY)): Current going out from the YYY terminal of jack XX.
Jxx(BBB): Terminal or pin BBB of jack xx
Jxx ON: Internal jumper Jxx terminals are shorted
Jxx OFF: Internal jumper Jxx terminals are open
Jxx (-YY-) ON: Internal jumper Jxx adjacent terminals marked as “YY” are shorted
Measure → A,B Check specified parameters A, B. If measured values are not within specified limits
the unit under test has failed.
Observe → A,B Observe if A, B occur. If they do not occur, the unit under test has failed.
Assembly drawings have location for jumpers, test points and individual components.
2.2 Safety
• Safety Glasses are to be worn.
• This test must be performed by qualified personnel trained in electronics theory and understand the
risks and hazards of the assembly to be tested.
• ESD precautions must be followed while handling electronic assemblies while performing this test.
• Precautions should be observed to avoid touching areas of the assembly that may get hot or present a
shock hazard during testing.
2.3 Quality
• Test data shall be made available upon request by Texas Instruments.
2.4 Apparel
• Electrostatic smock
• Electrostatic Gloves or finger cots
• Safety Glasses
• Ground ESD wrist strap
2.5 Equipment
• Power Supplies
Power Supply #1 (PS#1): a power supply capable of supplying 30-V at 5-A is required.
• Loads
LOAD #1 A 20V (or above), 3A (or above) electronic load that can operate at constant current and
constant voltage mode.
• Meters
Five Fluke 75 multi-meters, (equivalent or better)
4
600-kHz Synchronous Switch-Mode Li-Ion and Li-Polymer Host-Controlled SLVU495B–July 2011–Revised January 2012
Battery Charger With Integrated MOSFETs
Submit Documentation Feedback
Copyright © 2011–2012, Texas Instruments Incorporated