Datasheet
++
PS # 1
+ 5 V
+
bq24090/1
www.ti.com
Test Summary
4.1 Equipment
• Power supply +5.1 ±0.1 V, current limit set to 1.5 ±0.1 A
• Battery: 4.2 V LiCoO2 or equivalent
• Three Fluke 75 DMMs (equivalent or better)
• Oscilloscope, Model TDS220 (equivalent or better)
4.2 Equipment and EVM Setup
Jack/Component Connect or Adjustment To:
J1–DC+ Power supply positive, preset to 5 VDC, 1-A current limit.
J1–DC– Power supply ground
J2–BAT+ Positive Battery Pack Terminal
J2–BAT– Negative Battery Pack Terminal
JMP1 Apply shunt for Pre-TERM connection.
JMP2 Apply shunt for PG LED connection.
JMP3 Apply shunt for ISET2: ISET2-LO (pins 2-3) connection.
JMP4 Apply shunt for CHG LED connection.
JMP5 Apply shunt for TS connection.
R2 (R
ISET
) Adjust R2 for 1k between TP2 and GND
R3 (R
PRE-TERM
) Adjust R4 for 2k between TP4 and GND
R11 ( R
TS
) Adjust R11 for 10k between TP9 and GND
Figure 1. EVM Setup
3
SLUU392A–December 2009–Revised June 2010 1.0-A Single-Input, Single-Cell Li-Ion Battery Charger
Copyright © 2009–2010, Texas Instruments Incorporated