Datasheet

Battery Preconditioning
I
O(PRECHG)
=
K
(SET) (PRECHG)
x V
R
SET
(1)
Battery Fast-Charge Constant Current
I =
O(OUT)
K V
(SET) (SET)
x
R
SET
(2)
Charge-Current Monitor
(3)
Battery Fast-Charge Voltage Regulation
Charge Termination Detection and Recharge
I
O(TERM)
=
K V
(SET) (TERM)
x
R
SET
(4)
Sleep Mode
bq24083
SLUS848A MAY 2008 REVISED APRIL 2009 ..............................................................................................................................................................
www.ti.com
During a charge cycle, if the battery voltage is below the V
(LOWV)
threshold, the device applies a precharge
current, I
O(PRECHG)
, to the battery. This feature revives deeply discharged cells. Resistor R
SET
, connected
between the ISET and V
SS
, determines the precharge rate. The V
(PRECHG)
and K
(SET)
parameters are specified in
the Electrical Characteristics table.
The device activates a safety timer, t
(PRECHG)
, during the conditioning phase. If the V
(LOWV)
threshold is not
reached within the timer period, the device turns off the charger and enunciates FAULT on the STATx pins. See
the Timer Fault Recovery section for additional details.
The device offers on-chip current regulation with programmable set point. Resistor R
SET
, connected between the
ISET and V
SS
, determines the charge rate. The V
(SET)
and K
(SET)
parameters are specified in the specifications
table.
When the charge function is enabled internal circuits generate a current proportional to the charge current at the
ISET pin. This current, when applied to the external charge current programming resistor R
ISET
generates an
analog voltage that can be monitored by an external host to calculate the current sourced from the OUT pin.
The voltage regulation feedback is through the OUT pin. This input is tied directly to the positive side of the
battery pack. The device monitors the battery-pack voltage between the OUT and V
SS
pins. When the battery
voltage rises to the V
O(REG)
threshold, the voltage regulation phase begins and the charging current begins to
taper down.
As a safety backup, the device also monitors the charge time in the charge mode. If charge is not terminated
within this time period, t
(CHG)
, the charger is turned off and FAULT is set on the STATx pins. See the Timer Fault
and Recovery section for additional details.
The device monitors the charging current during the voltage regulation phase. Once the termination threshold,
I
(TERM)
, is detected, charge is terminated. The V
(TERM)
and K
(SET)
parameters are specified in the specifications
table.
After charge termination, the device restarts the charge once the voltage on the OUT pin falls below the V
(RCH)
threshold. This feature keeps the battery at full capacity at all times.
The device monitors the charging current during the voltage regulation phase. Once the termination threshold,
I
(TERM)
, is detected, the charge is terminated immediately.
Resistor R
SET
, connected between the ISET and V
SS
, determines the current level at the termination threshold.
The device enters the low-power sleep mode if the input power (IN) is removed from the circuit. This feature
prevents draining the battery during the absence of input supply.
12 Submit Documentation Feedback Copyright © 2008 2009, Texas Instruments Incorporated
Product Folder Link(s) :bq24083