REVISION HISTORY
Note: Page numbers of current revision may differ from previous versions.
Changes from Original (September 2008) to Revision A Page
• Changed device Features. .................................................................................................................................................... 1
• Changed Description. ........................................................................................................................................................... 1
• Changed Typical Application Circuit ..................................................................................................................................... 1
• Changed description of CHG pin. ......................................................................................................................................... 6
• Changed SYSOFF Description. ............................................................................................................................................ 7
• Changed the Simplified Block Diagram ................................................................................................................................ 8
• Added Figure 4 through Figure 11. ....................................................................................................................................... 9
• Changed APPLICATION CIRCUITS section. ..................................................................................................................... 12
• Added Using bq24075 to Disconnect the Battery from the System, Figure 28. ................................................................. 13
• Changed DETAILED FUNCTIONAL DESCRIPTION section. ............................................................................................ 16
• Changed text in section - STATUS INDICATORS (PGOOD, CHG) .................................................................................. 25
• Changed Table - CHG STATUS INDICATOR .................................................................................................................... 25
• Changed Equation 2 and Equation 3 .................................................................................................................................. 27
• Changed section - Half-Wave Adaptors ............................................................................................................................. 31
Changes from Revision A (December 2008) to Revision B Page
• Changed V
BAT(REG)
max value From 4.24 V To: 4.23 V ........................................................................................................ 5
Changes from Revision B (January 2009) to Revision C Page
• Changed Maximum input current factor values. ................................................................................................................... 4
Changes from Revision C (March 2009) to Revision D Page
• Added Device number bq24079. .......................................................................................................................................... 1
Changes from Revision D (June 2009) to Revision E Page
• Changed globally RT1 and RT2 to Rs and Rp ................................................................................................................... 27
• Added equations 2 and 3 plus explanations and table ....................................................................................................... 27
Changes from Revision E (August 2010) to Revision F Page
• Changed 10 x 45 s/kΩ to 10 x 48 s/kΩ under section Program 6.25hour......(TMR) ......................................................... 29
Changes from Revision F (September 2010) to Revision G Page
• Added ESD human body model specification to Abs Maximum Ratings table. ................................................................... 3
Changes from Revision G (July 2011) to Revision H Page
• Changed I
CHG
Battery fast charge current range MIN specification from "300 mA" to "150 mA" ......................................... 5
32 Submit Documentation Feedback Copyright © 2008–2014, Texas Instruments Incorporated