Datasheet

SLUU156 April 2003
5
bq24022 (bqTINY-II) Evaluation Module
1.2 Performance Specification Summary
Table 1. Performance Specification Summary
(1)
SPECIFICATION
TEST CONDITIONS MIN TYP MAX UNIT
Input DC voltage, V
I(DC)
V
REG
+ 0.5 5.0 5.2 V
Battery charge current
(1)
, I
O(CHG)
0.7 1.0 A
Power dissipation I
CHG
× (V
(DC+)
V
(BAT+)
) 1.5 W
(1) This input voltage maximum is a function of the maximum allowable power dissipation on the device. The current level is
programmed for 0.7 A. If the programmed charge is changed, then the maximum input voltage needs to be adjusted.
P
MAX(IC
) = 1.5 W = I
CHG
(V
(DC+)
V
(BAT+)
). The device has a maximum recommended operation of 6.5 VDC.
2 Test Summary
This section shows the test setups used, and the tests performed, in evaluating the EVM. See the
bq24020 datasheet (SLUS549) for complete details regarding the operation and specifications.
2.1 Test Setup
The bq24022 EVM board requires a regulated 5-VDC, 1-A power source or a USB, 0.5-A port maximum),
to provide input power and a single-cell Li-Ion or Li-Pol battery pack.
NOTE: If powered from an USB, 0.1-A port, make sure ISET2 is pulled low to program the board for the
100mA charge. Skip any test steps that program the UUT to 0.5 A.
The test setup connections and jumper setting selections are configured for a stand-alone evaluation but
can be changed to interface with external hardware such as a microcontroller.
Table 2. I/O and Jumper Connections(1)
JACK CONNECTION
J1DC+
Power supply positive connection, preset to 5.0VDC, 1.2A current limit. Can also be powered by J2 (USB) if J1
power is absent.
J1DC Power supply return connection, ground
J2USB plug USB 0.5-A port source for charging when J1 source is absent
J5BAT+ Positive battery pack terminal
J5BAT Negative battery pack terminal, BAT is common with DC
J5CE NC R4 is a pull down resistor, set to 20 k, to enable charging. J5CE can be used as an external control.
J5BAT N/C, optional external use
J3 (jumper) ISET2 program 0.5A (HIGH) | 0.1 A (LOW)
J4 (jumper) Power good Indication location LED (EVM) | EXT
J6 (jumper) BIAS power for EVM (jumper to active source) DC+ | USB
J7 (jumper) STAT1 indication location LED (EVM) | EXT
J9 (jumper) STAT2 indication location LED (EVM) | EXT
J8STAT1 External monitor hardware if J7EXT is jumpered (not jumpered from factory)
J8STAT2 External monitor hardware if J9EXT is jumpered (not jumpered from factory)
J10 PG External monitor hardware if J4EXT is jumpered (not jumpered from factory)
J10ISET2
External USB load control (TTL) HIGH (500 mA) | LOW (100 mA) (remove jumper J3 when using J10ISET2.
EVM set up for local control with jumper J3–0.1 A installed.
(1) Factory jumper selections are shown in BOLD