Datasheet
www.ti.com
bq24020 , , bq24022 , , bq24023
bq24024 , bq24025 , bq24026
bq24027
SLUS549E – DECEMBER 2002 – REVISED NOVEMBER 2007
Terminal Functions
TERMINAL
NAME I/O DESCRIPTION
bq24020 bq24022
bq24023 bq24024 bq24026
bq24025 bq24027
AC 1 1 1 1 1 I AC charge input voltage
CE 8 9 8 - - I Charge enable input (active low)
Charge current set point for AC input and precharge and taper
ISET1 6 6 6 6 6 I
set point for both AC and USB
Charge current set point for USB port (high=500 mA, low=100
ISET2 7 7 7 7 7 I
mA, hi-z = disable USB charge)
OUT 10 10 10 10 10 O Charge current output
PG - 8 - - - O powergood status output (active low)
STAT1 3 3 3 3 3 O Charge status output 1 (open-drain)
STAT2 4 4 4 4 4 O Charge status output 2 (open-drain)
TE - - - - 8 I Timer enable input (active low)
TS 9 - - 9 9 I Temperature sense input
TTE - - 9 8 - I Timer and termination enable input (active low)
USB 2 2 2 2 2 I USB charge input voltage
VSS 5 5 5 5 5 - Ground input
There is an internal electrical connection between the exposed
thermal pad and VSS pin of the device. The exposed thermal
Exposed
pad must be connected to the same potential as the VSS pin
Thermal pad pad pad pad pad -
on the printed circuit board. Do not use the thermal pad as
Pad
the primary ground input for the device. VSS pin must be
connected to ground at all times
Copyright © 2002 – 2007, Texas Instruments Incorporated Submit Documentation Feedback 7
Product Folder Link(s): bq24020 bq24022 bq24023 bq24024 bq24025 bq24026 bq24027