Datasheet

www.ti.com
Gas Gauging
LED Display
LifeTime Data Logging Features
Authentication
Power Modes
CONFIGURATION
Oscillator Function
bq20z80-V102
SLUS681B NOVEMBER 2005 REVISED JANUARY 2007
FEATURE SET (continued)
The bq20z80 uses the Impedance Track™ Technology to measure and calculate the available charge in battery
cells. The archievable accuracy is better than the coloumb counting method over the lifetime of the battery and
there is no full charge discharge learning cycle required.
See Theory and Implementation of Impedance Track Battery Fuel-Gauging Algorithm application note
(SLUA364) for further details.
The bq20z80 can drive 3-, 4-, or 5- segment LED display for remaining capacity indication.
The bq20z80 offers a lifetime data logging array, where all important measurements are stored for warranty and
analysis purposes. The data monitored includes:
Lifetime maximum temperature
Lifetime minimum temperature
Lifetime maximum battery cell voltage
Lifetime minimum battery cell voltage
Lifetime maximum battery pack voltage
Lifetime minimum battery pack voltage
Lifetime maximum charge current
Lifetime maximum discharge current
Lifetime maximum charge power
Lifetime maximum discharge power
Lifetime maximum average discharge current
Lifetime maximum average discharge power
Lifetime average temperature
The bq20z80 supports authentication by the host using SHA-1.
The bq20z80 supports 3 different power modes to reduce power consumption:
In Normal Mode, the bq20z80 performs measurements, calculations, protection decicions, data update in 1
second intervals. Between these intervals, the bq20z80 is in a reduced power stage.
In Sleep Mode, the bq20z80 performs measurements, calculations, protection decicions, data update in
adjustable time intervals. Between these intervals, the bq20z80 is in a reduced power stage.
In Shutdown Mode the bq20z80 is completety disabled.
The oscillator of the bq20z80 can be set up for internal or external operation. On power up, the bq20z80
automatically attempts to start the internal oscillator. If a 100-k resistor is not connected to ROSC (pin 33),
then it attempts to start the oscillator using an external 32.768-kHz crystal.
NOTE:
Install either the 100-k ROSC resistor or the 12-pF, 32.768-kHz crystal. Do not
install both.
9
Submit Documentation Feedback