Datasheet

www.ti.com
bq20z80-V102
SLUS681B NOVEMBER 2005 REVISED JANUARY 2007
Table 2. EXTENDED SBS COMMANDS
SBS Mode Name Format Size in Min Value Max Value Default Value Unit
Cmd Bytes
0x45 R AFEData String 11+1 ASCII
0x46 R/W FETControl hex 1 0x00 0xff
0x4f R StateOfHealth unsigned int 1 0 100 %
0x50 R SafetyAlert hex 2 0x0000 0xffff
0x51 R SafetyStatus hex 2 0x0000 0xffff
0x52 R PFAlert hex 2 0x0000 0xffff
0x53 R PFStatus hex 2 0x0000 0xffff
0x54 R OperationStatus hex 2 0x0000 0xffff
0x55 R ChargingStatus hex 2 0x0000 0xffff
0x57 R ResetData hex 2 0x0000 0xffff
0x58 R WDResetData unsigned int 2 0 65535
0x5a R PackVoltage unsigned int 2 0 65535 mV
0x5d R AverageVoltage unsigned int 2 0 65535 mV
0x60 R/W UnSealKey hex 4 0x00000000 0xffffffff
0x62 R/W PFKey hex 4 0x00000000 0xffffffff
0x63 R/W AuthenKey3 hex 4 0x00000000 0xffffffff
0x64 R/W AuthenKey2 hex 4 0x00000000 0xffffffff
0x65 R/W AuthenKey1 hex 4 0x00000000 0xffffffff
0x66 R/W AuthenKey0 hex 4 0x00000000 0xffffffff
0x70 R/W ManufacturerInfo String 8+1
0x71 R/W SenseResistor unsigned int 2 0 65535 µ
0x77 R/W DataflashClass hex 2 0x0000 0xffff
0x78 R/W DataFlashSubClass1 hex 32
0x79 R/W DataFlashSubClass2 hex 32
0x7a R/W DataFlashSubClass3 hex 32
0x7b R/W DataFlashSubClass4 hex 32
0x7c R/W DataFlashSubClass5 hex 32
0x7d R/W DataFlashSubClass6 hex 32
0x7e R/W DataFlashSubClass7 hex 32
0x7f R/W DataFlashSubClass8 hex 32
Table 3. DATAFLASH VALUES
Class Subclass Subclass Offset Name Data Min Value Max Value Default Units
ID Type Value
1st Level 0 Voltage 0 COV Threshold U2 3700 5000 4300 mV
Safety
2 COV Time U1 0 60 2 Sec
3 COV Recovery U2 0 4400 3900 mV
5 COV Delta U1 0 200 20 mV
6 COV Temp. Hys U1 0 250 100 0.1 ° C
7 POV Threshold U2 0 18000 17500 mV
9 POV Time U1 0 60 2 Sec
10 POV Recovery U2 0 17000 16000 mV
12 CUV Threshold U2 0 3500 2200 mV
14 CUV Time U1 0 60 2 Sec
15 CUV Recovery U2 0 3600 3000 mV
17 PUV Threshold U2 0 16000 11000 mV
19 PUV Time U1 0 60 2 Sec
20 PUV Recovery U2 0 16000 12000 mV
12
Submit Documentation Feedback