Datasheet
Data Logging
4-6
4.5 Data Logging
1) Select Options|Logging Options to select the registers to log and set the
logging interval.
2) File|Start Data Log from the pulldown menu.
3) Enter the name of the data log file in the Name Datalog File box
4) Click on the Open button
5) To stop the data logging select File|Close Data Log from the pulldown
menu. The file can be imported into a text editor, spreadsheet, or word
processor program.
Example data log:
EV2201–23 Version: 1.0.0
Texas Instruments bq2023 battery monitor
06/04/2001 2:40:35 PM
ROM ID: 74 50 01 10 B2 03 00 B
Sample Stamp Elapsed (s) DCR CCR SCR DTC CTC MODE/WOE CLR TEMP
1 2:40:45 PM 10 0 0 0 0 16 78 192 1186
2 2:40:55 PM 20 0 0 0 0 26 78 192 1186
3 2:41:05 PM 30 0 0 0 0 37 78 192 1187
4 2:41:15 PM 40 5 0 0 4 44 78 192 1187
5 2:41:25 PM 50 9 0 0 15 44 78 192 1187
6 2:41:35 PM 60 9 0 0 25 44 78 192 1188
7 2:41:45 PM 70 9 0 0 46 44 78 192 1188
8 2:41:55 PM 80 9 0 0 56 44 78 192 1196
9 2:42:05 PM 90 10 0 0 66 44 78 192 1194