Datasheet

AMC80EVM Software Overview
www.ti.com
5.2.4 Local Temperature
The AMC80 local temperature sensor data are displayed in degrees Celsius (°C) and has programmable
temperature limits, as indicated in Figure 16. The temperature interrupt indicators turn bright green when a
limit has been exceeded.
Figure 16. Max Temp Flag Trigger
5.2.5 Interrupt Inputs
Toggling the buttons in the Write Interrupt Inputs box shown in Figure 17 and clicking the Write all Reg
button changes the values of the interrupt inputs to the AMC80. Clicking Read all Reg reveals the status
of the interrupt registers via the Read Interrupt Inputs indicators. Note that these registers clear only once
the input returns to a false value and the register has been read. Clicking the RESET button toggles the
RST_IN interrupt to the AMC80 low for 50ms.
Figure 17. Interrupt Inputs
14
AMC80EVM SBOU101March 2011
Submit Documentation Feedback
© 2011, Texas Instruments Incorporated