Table 13. Analog Input Channel Range
STARTING CHANNEL ENDING CHANNEL
ECNVT CMODE ADC MODE [SA3:SA0] [EA3:EA0]
Any one from CH0 to
External trigger,
1 0 Any one of CH0 to CH8 CH8, but not less than
direct mode
[SA3:SA0]
Internal trigger,
0 CH0 only. SA3:SA0 = '0000' Any one
direct mode
0
Internal trigger,
1 CH0 only. SA3:SA0 = '0000' Any one
auto mode
ADC Data-n Registers (n = 0, 1, 2, 3, 4, 5, 6, 7, 8) (Read-Only)
Nine ADC Data registers are available. The ADC Data-n Registers store the conversion results of the
corresponding analog channel-n. The ADC-8 Data Register is used for the on-chip temperature sensor. The
other registers are for external analog inputs. All ADC Data-n registers are formatted in the manner shown here.
Bit 15 Bit 0
MSB Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 LSB
ICH3 ICH2 ICH1 ICH0 ADC1 ADC1 ADC9 ADC8 ADC7 ADC6 ADC5 ADC4 ADC3 ADC2 ADC1 ADC0
1 0
ADC11–ADC0 Value of the conversion result. The data are updated when the conversion of the input
[EA3:EA0] finishes; see the ADC Operation section for details.
ICH3–ICH0 Analog Input Channel number
After power-on or reset, all bits are cleared to '0'.
All ADC Data-n Registers are read-only. Writing to the ADC Data-n registers does not cause any change.
Table 14 summarizes the ADC Data-n Registers.
Table 14. ADC Data-n Registers
ICH3 ICH2 ICH1 ICH0 ANALOG INPUT
0 0 0 0 CH0
0 0 0 1 CH1
0 0 1 0 CH2
0 0 1 1 CH3
0 1 0 0 CH4
0 1 0 1 CH5
0 1 1 0 CH6
0 1 1 1 CH7
1 0 0 0 CH8