Datasheet

AMC7812
www.ti.com
SBAS513E JANUARY 2011REVISED SEPTEMBER 2013
Table 26. AUTO-DAC-CLR-SOURCE Register (continued)
BIT NAME DEFAULT R/W DESCRIPTION
CH3 alarm clear bit.
If CH3-ALR_CLR = '1', and if both the ACLRn bit in the AUTO-DAC-CLR-EN Register and
11 CH3-ALR-CLR 0 R/W the CH3-ALR bit in the Status Register are set ('1'), then DACn is forced to a clear status.
If CH3-ALR_CLR = '0', then CH3-ALR goes to '1' and does not force any DAC to a clear
status.
Local temperature sensor low alarm clear bit.
If LT-Low-ALR-CLR = '1', and if both the ACLRn bit in the AUTO-DAC-CLR-EN Register
LT-Low-ALR- and the LT-Low-ALR bit in the Status Register are set ('1'), then DACn is forced to a clear
10 0 R/W
CLR status.
If LT-Low-ALR-CLR = '0', then LT-Low-ALR goes to '1' and does not force any DAC to a
clear status.
Local temperature sensor high alarm clear bit.
If LT-High-ALR-CLR = '1', and if both the ACLRn bit in the AUTO-DAC-CLR-EN Register
LT-High-ALR- and the LT-High-ALR bit in the Status Register are set ('1'), then DACn is forced to a clear
9 0 R/W
CLR status.
If LT-High-ALR-CLR = '0', then LT-High-ALR goes to '1' and does not force any DAC to a
clear status.
Remote temperature sensor D1 low alarm clear bit.
If D1-Low-ALR-CLR = '1', and if both the ACLRn bit in the AUTO-DAC-CLR-EN Register
D1-Low-ALR- and the D1-Low-ALR bit in the Status Register are set ('1'), then DACn is forced to a clear
8 0 R/W
CLR status.
If D1-Low-ALR-CLR = '0', then D1-Low-ALR goes to '1' and does not force any DAC to a
clear status.
Remote temperature sensor D1 high alarm clear bit.
If D1-High-ALR-CLR = '1', and if both the ACLRn bit in the AUTO-DAC-CLR-EN Register
D1-High-ALR- and the D1-High-ALR bit in the Status Register are set ('1'), then DAC n is forced to a clear
7 0 R/W
CLR status.
If D1-High-ALR-CLR = '0', then D1-High-ALR goes to '1' and does not force any DAC to a
clear status.
Remote temperature sensor D2 low alarm clear bit.
If D2-Low-ALR-CLR = '1', and if both the ACLRn bit in the AUTO-DAC-CLR-EN Register
D2-Low-ALR- and the D2-Low-ALR bit in the Status Register are set ('1'), then DACn is forced to a clear
6 0 R/W
CLR status.
If D2-Low-ALR-CLR = '0', then D2-Low-ALR goes to '1' and does not force any DAC to a
clear status.
Remote temperature sensor D2 high alarm clear bit.
If D2-High-ALR-CLR = '1', and if both the ACLRn bit in the AUTO-DAC-CLR-EN Register
D2-High-ALR- and the D2-High-ALR bit in the Status Register are set ('1'), then DAC n is forced to a clear
5 0 R/W
CLR status.
If D2-High-ALR-CLR = '0', then D2-High-ALR goes to '1' and does not force any DAC to a
clear status.
D1 fail alarm clear bit.
If D1-FAIL-CLR = '1', and if both the ACLRn bit in the AUTO-DAC-CLR-EN Register and
the D2-FAIL-ALR bit in the Status Register are set ('1'), then DACn is forced to a clear
4 D1-FAIL-CLR 0 R/W
status.
If D1-FAIL-ALR-CLR = '0', then D1-FAIL-ALR goes to '1' and does not force any DAC to a
clear status.
D2 fail alarm clear bit.
If D2-FAIL-CLR = '1', and if both the ACLRn bit in the AUTO-DAC-CLR-EN Register and
the D2-FAIL-ALR bit in the Status Register are set ('1'), then DACn is forced to a clear
3 D2-FAIL-CLR 0 R/W
status.
If D2-FAIL-ALR-CLR = '0', then D2-FAIL-ALR goes to '1' and does not force any DAC to a
clear status.
Thermal alarm clear bit.
If THERM-ALR-CLR = '1', and if both the ACLRn bit in the AUTO-DAC-CLR-EN Register
THERM-ALR- and the THERM-ALR bit in the Status Register are set ('1'), then DACn is forced to a clear
2 1 R/W
CLR status.
If THERM-ALR-CLR = '0', then THERM-ALR goes to '1' and does not force any DAC to a
clear status.
1 0 R Reserved. Writing to this bit causes no change. Reading this bit returns '0'.
0 0 R Reserved. Writing to this bit causes no change. Reading this bit returns '0'.