Remote TEMP-FAN Control Register (Address 0x25, Value After Power-On or Reset = 0x61)
BIT NAME DEFAULT DESCRIPTION
7 R-TEMP4 0 Low Temperature Bit of Remote Sensor
6 R-TEMP3 1 R-TEMP4 R-TEMP3 R-TEMP2 R-TEMP1 R-TEMP0 Low Temp
5 R-TEMP2 1 0 0 0 0 0 0 ° C
4 R-TEMP1 0 0 0 0 0 1 4 ° C
3 R-TEMP0 0 0 0 0 1 0 8 ° C
0 0 0 1 1 12 ° C
... ... ... ... ... ...
0 1 1 0 0 48 ° C (Default)
... ... ... ... ... ...
1 1 1 1 0 120 ° C
1 1 1 1 1 124 ° C
2 R-SLP2 0 Slope Bits of Remote Sensor
1 R-SLP1 0 Slope
Temp Range in ° C
0 R-SLP0 1 R-SLP2 R-SLP1 R-SLP0 LSB/ ° C %/ ° C (DCY 33.3% to 100%)
0 0 0 32 12.55 5.31
0 0 1 16 6.27 10.62 (default)
0 1 0 8 3.14 21.25
0 1 1 4 1.57 42.5
1 0 0 2 0.78 85
This register specifies the parameters of the Remote Temperature-Fan Control mode.
Low Temperature Bits: [R-TEMP 4:R-TEMP0]
These bits specify the low temperature of the auto remote temperature-fan control. In this control mode, the duty
cycle is equal to the value of the DCY-LOW-TEMP register when the remote temperature is less than or equal to
the value defined by bits [R-TEMP4:R-TEMP0].
Slope Bits: [R-SLP2:R-SLP0]
These bits define the increment of the duty cycle when the remote temperature rises every 1 ° C in the auto
remote temperature-fan control.