Datasheet

Data Registers (addresses 0x1D, 0x1F, 0x21 and 0x23)
Time Registers (addresses 0x1E, 0x20, 0x22 and 0x24)
AMC1210
www.ti.com
.............................................................................................................................................................. SBAS372D APRIL 2006 REVISED MAY 2009
The Data Registers store the latest data from either the sinc filter or the integrator output for each filter module.
The data is presented in two's complement 16-bit or 32-bit format. The bit DR in the Integrator Parameter
Register controls the bit width of the Data Register. It takes two bytes to read the 16-bit formatted data and four
bytes to read the 32-bit formatted data. The acknowledge flag for the appropriate filter module is cleared when
reading the Data Register. Table 24 describes the Data Register in 16-bit formatting.
Table 24. Data Register (16-Bit Format)
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
'0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0'
R R R R R R R R R R R R R R R R
BIT POSITION BIT DESCRIPTION
15 0 D15 D0 Data from the sinc filter or the integrator filter in 16-bit formatting.
Table 25 describes the Data Register in 32-bit formatting.
Table 25. Data Register (32-Bit Format)
Bit 31 Bit 30 Bit 29 Bit 28 Bit 27 Bit 26 Bit 25 Bit 24 Bit 23 Bit 22 Bit 21 Bit 20 Bit 19 Bit 18 Bit 17 Bit 16
D31 D30 D29 D28 D27 D26 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16
'0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0'
R R R R R R R R R R R R R R R R
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
'0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0'
R R R R R R R R R R R R R R R R
BIT POSITION BIT DESCRIPTION
31 0 D31 D0 Data from the sinc filter or the integrator filter in 32-bit formatting.
The Time Registers store the latest time information for each filter module. The data is presented in straight
binary 16-bit format. The bit TMx in the Control Parameter Register controls the mode of the time measure unit.
Table 26 describes the Time Registers.
Table 26. Time Registers
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
TD15 TD14 TD13 TD12 TD11 TD10 TD9 TD8 TD7 TD6 TD5 TD4 TD3 TD2 TD1 TD0
'0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0' '0'
R R R R R R R R R R R R R R R R
BIT POSITION BIT DESCRIPTION
15 0 TD15 TD0 Data from the time measure unit.
Copyright © 2006 2009, Texas Instruments Incorporated Submit Documentation Feedback 37
Product Folder Link(s): AMC1210